567
S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_hpib_setup_tferror.fm
SETup:TFERror
SETup:TFERror:TIMeout[:STIMe]
SETup:TFERror:TIMeout:STATe
SETup:TFERror:TIMeout:TIME
Function The setting form of this command performs two functions: (1) sets the TDSO frame error rate
measurements timeout (see Timeouts ) value, and (2) sets the TDSO frame error rate
measurements timeout STATe to 1 (on).
The query form returns the TDSO frame error rate measurements timeout value.
Setting Range: 0.1 to 200000.0 seconds
Resolution: 0.1 second
Query Range: 0.1 to 200000.0
*RST Setting 200 seconds, off
Programming Example
OUTPUT 714;"SETUP:TFERROR:TIMEOUT:STIME 120 S"
!Sets timeout state to ON and sets the timeout time to 120 seconds.
Function Sets/queries the test data service option (TDSO) frame error rate measurements timeout (see
Timeouts ) state.
Setting Range: 1|ON|0|OFF
Query Range: 1|0
*RST Setting 0 (off)
Programming Example
OUTPUT 714;"SETUP:TFERROR:TIMEOUT:STATE ON"
Function Sets/queries the test data service option (TDSO) frame error rate measurements timeout (see
Timeouts ) setting to be used when the timeout state is set to ON.
Setting Range: 0.1 to 200000.0 seconds
Resolution: 0.1 second
Query Range: 0.1 to 200000.0 seconds
*RST Setting 200 seconds
Programming Example
OUTPUT 714;"SETUP:TFERROR:TIMEOUT:TIME 120 S"