S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_ts_err_msg_neg100.fm
-100 through -199 Error Message Descriptions
-100 through -199 Error Message Descriptions
Description
A command error indicates that the test set’s GPIB parser has detected an IEEE 488.2 syntax error.
When one of these errors is generated, the command error bit in the event status register is set.
Error Message Description
-100 Command error This event bit (Bit 5) indicates a syntax error, or a
semantic error, or a GET command was entered, see
IEEE 488.2, 11.5.1.1.4.
-101 Invalid character Indicates a syntactic elements contains a character
which is invalid for that type.
-102 Syntax error Indicates that an unrecognized command or data type
was encountered. For example, a string was received
when the device does not accept strings.
-103 Invalid separator The parser was expecting a separator and encountered
an illegal character. For example, the semicolon was
omitted after a program message unit.
-104 Data type error The parser recognized a data element different than
one allowed. For example, numeric or string data was
expected but block data was encountered.
-105 Get not allowed Indicates a Group Execute Trigger was received within
a program message. Correct the program so that the
GET does not occur within the program code.
-108 Parameter not allowed Indicates that more parameters were received than
expected for the header. For example, *ESE common
command only accepts one parameter, so *ESE 0,1 is
not allowed.
-109 Missing parameter Indicates that less parameters were received than
required for the header. For example, *ESE requires
one parameter, *ESE is not allowed.
-110 Command header error Indicates an error was detected in the header. This
error is used when the device cannot detect the more
specific errors -111 through -119.
-111 Header separator error Indicates that a character that is not a legal header
separator was encountered while parsing the header.
-112 Program mnemonic too long Indicates that the header contains more that twelve
characters, see IEEE 488.2, 7.6.1.4.1.

Table of Contents

Other manuals for Agilent Technologies 8960 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 8960 Series and is the answer not in the manual?

Agilent Technologies 8960 Series Specifications

General IconGeneral
BrandAgilent Technologies
Model8960 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals