S:\Hp8960\E1962B CDMA 2000\Pi Release\Reference Guide\Chapters\cdma2000_meas_adherence_desc.fm
Test Adherence to Standards
4.4.2 Time Response of Open Loop Power Control No
4.4.3 Access Probe Output Power Yes, use call limit feature to prevent call from connecting.
Support for SR1 and SR3 Enhanced Access Channel is a
possible future enhancement.
4.4.4 Range of Closed Loop Power Control Yes, but does not make timing measurements. Test 2 not
supported.
4.4.5 Maximum RF Output Power Yes. Spurious emissions requires an external spectrum
analyzer.
4.4.6 Minimum Controlled Output Power Uses channel power measurement.
4.4.7 Standby Output Power and Gated Output Power Partially, the E1962B has graphical Gated Power
measurements.
4.4.8 Power up Function Output Power No
4.4.9 Code Channel to Reverse Pilot Output Power
Accuracy
Yes, except Enhanced Access Channel Header, Enhanced
Access Channel Data and Reverse Common Control
Channel Data.
4.4.10 Reverse Pilot Channel Phase Discontinuity No. The test set provides call setup. HP859XE and HP
85725C are needed to make the measurement.
4.5.1 Conducted Spurious Emissions Yes.
4.5.2 Radiated Spurious Emissions Yes. Requires external spectrum analyzer.
4.5.3 Occupied Bandwidth (Band classes 3 & 6 only) Yes. Requires external spectrum analyzer.
Table 8. IS-98-D Standards
TIA/EIA-98-D E1962B