EasyManua.ls Logo

Avaya S8700 - Page 1473

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ETH-PT (Control LAN Ethernet)
Issue 1 May 2002
8-751555-233-143
Link Integrity Inquiry Test (#1282)
This nondestructive test queries the C-LAN Ethernet ports physical
connections.
If: Then the test:
C-LAN connection is present, Passes.
C-LAN connection is absent, Fails.
There is no response, Aborts.
Table 8-294. Test #1282 Link Integrity Inquiry Test
Error
Code
Tes t
Result Description / Recommendation
1124 ABORT Ethernet link is not enabled.
1. Verify that the Ethernet link is enabled (status port UUCSSpp, status link
n, or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
4. Escalate if the problem persists.
1125 ABORT Ethernet link not in service.
1. Verify whether Ethernet link is in service (status port UUCSSpp or status
link n).
2. If the Ethernet link is not in service, release the link (release link n or
release port UUCSSpp).
3. Repeat the test.
4. Escalate if the problem persists.
1959 ABORT Downlink message error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
2100 ABORT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
Continued on next page