Maintenance-Object Repair Procedures
555-233-143
8-876 Issue 1 May 2002
Screen 8-6. Display Firmware Image(s) screen
4. Ensure that both the Active Image and the Reset Image fields are Yes for
Image 2.
NOTE:
The firmware image filename (the file that you downloaded to the
TN2501AP circuit pack) does not appear on this screen. Ensure that
you have copied the correct file to the circuit pack and have set the
proper firmware image file (set boot-image).
Error Log Entries and Test to Clear Values
Table 8-332. FW-DWNLD Maintenance Error Log Entries
Error
Type Aux Data Cause Of Error
Alarm
Level
On/Off
Board Test to Clear Value
257(a) See
associated
note
Download
failure
MINOR OFF test firmware download
UUCSS
258(b) See
associated
note
Download
failure
MINOR OFF test firmware download
UUCSS
259(c) See
associated
note
Download
failure
MINOR OFF test firmware download
UUCSS
513(d) See
associated
note
Download
failure
MINOR OFF test firmware download
UUCSS
796(e) See
associated
note
Firmware
download
request
MINOR OFF test firmware download
UUCSS
get boot-image 1C07
DISPLAY FIRMWARE IMAGE(S)
Image 1 Image 2
Board Type: TN2501 TN2501
FW Vintage: 02 02
HW Signature: 02 02
Suffix: A A
Date: 03/02/02 03/02/01
Timestamp: 10:30:50 12:42:18
CRC Checksum: Good Good
Active Image: Yes No
Reboot Image: Yes No