IPMEDPRO (IP Media Processor Circuit Pack)
Issue 1 May 2002
8-935555-233-143
Control Channel Loop-around Test (#52)
This test queries the circuit pack for its circuit pack code and vintage and verifies
its records.
SAKI Sanity Test (#53)
This is a destructive test.
This test is only run as a part of a reset board procedure. For the Media
processor, it is necessary to use the change ip-interfaces form to disable the
Media processor IP interface before performing this reset board procedure. Other
common circuit packs can be reset with the reset board UUCSS command which
also executes this test.
A reset of this circuit pack takes about 3½ minutes.
Table 8-361. Test #52 Control Channel Loop-around Test
Error
Code
Test
Result Description / Recommendation
None,
2100
ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The circuit pack failed to return the circuit pack code or vintage.
1. Retry the command up to 5 times.
2. If the problem continues, replace the circuit pack.
3. Retry the command up to 5 times.
PASS Communication with this circuit pack is successful.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Ensure that the board translations are correct. Administer the MedPro
interface if it is not already administered.
2. If the board was already administered correctly, check the error log to
determine whether the board is hyperactive. If this is the case, the board is
shut down. Reseating the board re-initializes the board.
3. If the board was found to be correctly inserted in step 1, then issue the
busyout board UUCSS command.
4. Issue the reset board UUCSS command.
5. Issue the release board UUCSS command.
6. Issue the test board UUCSS long command.
This should re-establish the linkage between the internal ID and the port.
Continued on next page