MAPD-BD (MAPD Interface Circuit Pack TN802)
Issue 1 May 2002
8-1045555-233-143
Table 8-416 lists the TN802 LCD messages that you might see if installing or
servicing an IP Trunk.
Support for Laptop PCs
Field technicians can access the TN802 circuit pack through:
1. ‘‘pcANYWHERE® Client Software’’
2. ‘‘Directly-Connected Keyboard, Monitor, Mouse’’
pcANYWHERE
®
Client Software
1. Attach a male-to-male serial cable and a NULL modem connector (if
not built into the cable you use) to the COM2 connector (Note 8 in
Figure 8-56 on page 8-1046) Attach the other end to the serial port
of your laptop.
2. Launch the pcANYWHERE
®
application.
3. Click on Add Remote Control Item.
4. In the Properties window, choose the communication port to which
you connected the cable in Step 1.
5. Click on Details and configure the settings (Table 8-417):
Table 8-416. TN802 LCD messages for IP trunks
Display Explanation
PC BOOT The TN802 MAPD PC is booting up.
IP TRK # IP Trunk application is running (# character blinks).
IML DWN # Internal error on the IP Trunk. System shuts down and
sends and error message to the board.
MSHUT #, where both
MSHUT and # are
blinking
The system is in the process of shutting down due to a front
panel button press. Do not attempt to remove board.
MSHUT #, where # is
blinking
The system has shut down gracefully.
Continued on next page