M/T-DIG (Maintenance/Test Digital Port)
Issue 1 May 2002
8-1173555-233-143
50 FAIL The switch was unable to communicate with the port circuitry used for digital
trunk testing.
100 FAIL Data was not sent from port 2 to port 3 successfully in asynchronous mode.
101 FAIL Data was not sent from port 3 to port 2 successfully in asynchronous mode.
102 FAIL Data was not sent from port 2 to port 3 successfully in synchronous mode.
103 FAIL Data was not sent from port 3 to port 2 successfully in synchronous mode.
1. Reset the circuit pack via the busyout board UUCSS, reset board
UUCSS, release board UUCSS command sequence.
2. Test the port again via the test port UUCSS02 l command.
3. If the test fails again, replace the circuit pack.
PASS The Maintenance/Test digital port digital trunk testing capability is operating
correctly.
Table 8-480. Test #565 Digital Port Sanity Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page