status bri-port
Issue 1 May 2002
7-297555-233-143
ASAI 0-63 Established blank blank This is a transitory state for ASAI
adjuncts. ASAI signaling is
connected at Layer 2 but the Layer 3
Restart procedure has not been
completed between switch and
adjunct.
1. Check the adjunct by following
the recommended repair
procedures of the manufacturer.
2. Repeat status bri-port and
determine whether the L2 state
of the signaling link is
L3-Established. If it is not,
follow normal escalation
procedures.
BRI 0-126 Established ext# blank This is the normal state for non-MIM
initializing, fixed, and automatic TEI
BRI endpoints.
BRI,
ASAI
64-126 Established blank blank This is a transitory state for
automatic TEI BRI endpoints that
support MIM initialization.
1. Verify that SPID administration
on the switch and the endpoint
are consistent. Repeat status
bri-port to determine whether
the Layer 2 state of the
signaling link is
L3-Established.
2. Try replacing the endpoint.
Repeat status bri-port to
determine whether the Layer 2
state of the signaling link is
L3-Established. If it is
not, follow normal escalation
procedures.
BRI 64-126 L3-Established ext# blank This is the normal state for
automatic TEI BRI endpoints that
support MIM initialization.
Table 7-45. Interpreting BRI-Port Status Reports Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page