ATM-BCH (ATM B-Channel Trunk)
Issue 1 May 2002
8-177555-233-143
1116 ABORT Trunk not in Out-of-Service/Far-end state and country protocol other than 1
1117 ABORT Service-state audit message outstanding
1. Wait 2 minutes, then try again.
2100 ABORT Could not allocate needed resources
1. Retry the command up to 5 times at 1-minute intervals.
1113 FAIL Signaling link failed
1. See the ‘‘ATM-SGRP (ATM Signaling Group)’’ and ‘‘ISDN-LNK (ISDN-PRI
Signaling Link Port)’’ MOs.
FAIL Internal system error
1. Retry the command up to 5 times at 1-minute intervals.
PASS 1. Wait 4 minutes, then check the Error Log for any new Error Type 3073.
If there are none, both sides of the ISDN connection agree on
the service state. The negotiation succeeded.
If there is a new 3073 error, then the negotiation failed (the
request timed out).
Table 8-72. Test #256 Service State Audit Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page