Configuration
Parameter manual b maXX BM3000
Document no.: 5.12001.07 Baumüller Nürnberg GmbH
212
of 820
4.4
1)
Speed_1 Z132.10– = Z132.14–
2)
Speed_2 Z132.12– = Z132.16–
52.2 Mean speed 1
Display of the determined speeds while the drive is being operated at constant speed
Speed_1.
52.3 Mean speed 2
Display of the determined speeds while the drive is being operated at constant speed
Speed_2.
14 End
15 Not used
16 Error: Time for speed Speed_1
1)
less than 2 seconds
17 Error: Time for speed Speed_2
2)
less than 2 seconds
18 Error: Time for acceleration less than 0.1 seconds
19 Error: Time for braking less than 0.1 seconds
20 Error: Time for Speed_1
1)
or Speed_2
2)
or acceleration or braking phases
greater than 120 seconds
21 Error: Set speed Speed_1 or Speed_2 too low, < 10 degrees/s
22 Error: Determined value of Ks would be negative because acceleration value
too low
23 Error: Determined value of Ks would be negative because acceleration value
too low during braking
24 Error: Speed deviation too great (>5%)
25 Error: Incorrect acceleration sign during acceleration or braking
26 Error: Set acceleration not equal to ZERO at constant speed
27 Error at the Ks measurement with FFT module
40 Start Ks measurement with FFT module
41 Wait until the FFT module is available
42 Measurement using the FFT module is active
43 Calculation of the speed controller parameters
Value Meaning