Description of the Software Modules and Parameters
Parameter manual b maXX BM3000
Document no.: 5.12001.07
337
of 820
4
n Action:
m None
8 OPERATION ENABLED DRIVE SHUT-DOWN ACTIVE
n Event:
m "Shut Down" command or
m Pulse enable input = Low
n Action:
Drive activation by control word:
m Drive shut-down is initiated (braked or coast-down, depending on setting, or coast
down if Pulse enable input = Low)
8a DRIVE SHUT-DOWN ACTIVE READY TO SWITCH ON
n Event:
m SHUT-DOWN response (Z108.14) is set to "Inhibit Drive Function" (Pulse Inhib-
it, value 0) or
m Drive Shut-down has ended (speed 0 reached)
m Pulse enable input = Low
n Action:
m Drive function is inhibited
9 OPERATION ENABLED SWITCH-ON INHIBIT
n Event:
m "Inhibit Voltage" command
n Action:
m Drive function is inhibited
10 SWITCHED ON SWITCH-ON INHIBIT
n Event:
m "Inhibit Voltage" command or
m "Quick Stop" command or
m Quick Stop input = Low (only if Quick Stop (QS) hardware control input is used)
n Action:
m Drive function is inhibited
11 OPERATION ENABLED QUICK STOP ACTIVE
n Event:
m "Quick Stop" command or
m Quick Stop input = Low (only if Quick Stop (SH) hardware control input is used)
n Action:
m Quick Stop is initiated (braked or coast-down, depending on setting)