Diagnosis
Parameter manual b maXX BM3000
Document no.: 5.12001.07 Baumüller Nürnberg GmbH
702
of 820
4.9
If it is not possible to start the recording, the available memory is insufficient.
If the ring buffer is in Status 4 (Waiting for Read Out), the recording can also be restarted
without read-out.
101.3 Channel 0 source parameter Id
Specification of the parameter ID of the signal to be recorded.
Only parameters with scalar data types can be recorded (no array elements, no structure
elements).
Only real-time capable parameters can be recorded for which the access function does
not exceed a specific minimum time. The controller checks the ID and reports a corre
-
sponding error message to the operating system if the parameters are not real-time ca-
pable.
101.4 Channel 1 source parameter Id
See Z101.3–
101.5 Channel 2 source parameter Id
See Z101.3–
101.6 Channel 3 source parameter Id
See Z101.3–
101.7 Channel 4 source parameter Id
See Z101.3–
NOTE!
Before a trigger event bit is accepted, the trigger ID and trigger axis mask must be
entered!