88 100-412-234 REV. 06
5.8.3 For a 40kHz System
*Loctite is a registered trademark of Henkel Corporation, U.S.A.
Table 5.12 For a 40kHz System
Step Action
1
Clean the mating surfaces of the converter, booster, and horn. Remove any
foreign material from the threaded holes.
2
Apply a drop of Loctite®* 290 thread-locker (or equivalent) to the studs for
the booster and horn.
3
Install the threaded stud into the top of the booster; torque to 70 in-lbs,
7.91 N·m, and let cure for 30 minutes.
4
Install the threaded stud into the top of the horn; torque to 70 in-lbs, 7.91
Nm, and let cure for 30 minutes.
5
Coat each interface surface with a thin film of silicon grease – but do not
apply silicon grease to a threaded stud or tip.
6 Screw the converter to the booster.
7 Torque to 95 in-lbs, 10.73N·m.
8
Slide the booster/horn assembly into the adapter sleeve. Screw on the
adapter sleeve ring nut and leave loose.
9 Screw the booster onto the horn.
10 Repeat Step 7.
11
Securely tighten the adapter sleeve ring nut with the spanner wrenches
shipped with the sleeve assembly.