100-412-234 REV. 06 279
D.3 Error Codes
Table D.1 Error Codes
Error
Code
Type Description
0 Success
All services will respond with this Error Code if there are
no errors preventing the web service from being
accepted.
1 Login Failure
This error will occur when attempting to login when
another user is already logged in. In order to prevent
this error from occurring, there can be no other users
logged in to the 2000Xc either from the web services OR
from the front panel.
2 Not Logged In
This error will occur when any service is requested but
the Login service has not yet been successful. Either
login via the Login web service or disable the Authority
Check option from the System Configuration menu.
3 Login Failure
This particular login failure will occur when the user
attempts to login with incorrect username or password
information.
4 Login Failure
This is a specific error code that comes when a user is
attempting to login for the first time. A first time login is
not permitted through the web services. The user must
use the front panel to modify his password after first
time login then use the web services.
5
Verify Preset
Failure
If verifying the preset fails for any reason, this error
code will be sent and the preset parameters must be
inspected.
6
System Not
Ready
This error code can be sent in reply to various service
requests. Most typically it is used when attempting to
modify or save a preset when the system is not in the
Ready state.
7 Range Error
This error code is specific to trying to set any value that
is out of bounds for the given parameter. This can be
anything from the system clock to weld parameters to
preset numbers.
8 Invalid Data
This error code is sent when the requested data to be set
is not a valid ID. For example, if setting a preset value is
sent with a param ID of 99999, this is not a valid value.
9 Range Error
This error code is sent if the data requested for a
specified range is not available. For example, if the
system only has 10 alarms and the data is requested
from 50 to 99, then this error will be generated.

Table of Contents