280 100-412-234 REV. 06
10
User Creation
Failure
This error code is sent when requesting to add another
user to the power supply list and the max number of
active users has already been met (500 active users).
This can also happen when attempting to modify a user
and the modification puts it over the max number of
active users.
11
User Creation
Failure
This error code is sent when requesting to add a new
user to the power supply database and the max number
of users have already been added (1000 users)
12
User Creation
Failure
This error code is sent when the password that is
requested to be made for a new user does not meet the
requirements. 1 Capital letter, 1 lower case letter, 1
number, 1 special character, between 8-10 total
characters.
13
Too Much
Data
This error is specifically sent in response to requests for
log data. Weld History, Alarm Logs, Event Logs, and User
ID table information are only able to be processed in
chunks of 50 entries at a time. If the web request is
made for more than 50 entries at a time, this error code
will be returned.
14
User Change
Failure
This error code is sent if the requested changes to a user
account cannot be made. For example, if the UserID
does not exist.
15
Unauthorized
Access
This error is sent whenever a user, most likely an
Operator, attempts to perform an action that they are
not authorized to make.
16 Login Failure
This error code is sent when the user’s password has
expired.
17
User Creation
Failure
This error code is sent specifically when the user ID that
is requested to be created already exists in the
database.
18 Login Failure
This error code is sent when the user has attempted to
login unsuccessfully too many times. This causes the
user to be locked out of the power supply.
19
Data Request
Failure
This error can occur if data is requested but cannot be
processed due to an internal connection failure. Retry
the web request if this error is received.
20 Invalid Data
This error code is sent when a change is made to the
system and a reason for change is required but was not
sent. Retry the web request but be sure to include the
“Reason” in the POST data.
21
Recall Preset
Failure
This error code occurs when an attempt is made to recall
a preset that has never been saved before.
Table D.1 Error Codes
Error
Code
Type Description

Table of Contents