100-412-234 REV. 06 209
8.8 Parts Replacement
The 2000Xc Power Supply is designed for a long service life. In the event the system
malfunctions, many of the internal components (Modules) are replaceable as a unit. If a
particular module has failed, it should be replaced or repaired at a Branson Depot Facility.
The 2000Xc system is designed with an extensive Alarms Message system. Refer to the
list of error messages to assist your troubleshooting. These error codes are described in
8.6 Troubleshooting.
The following parts are replaceable. Refer to the following views of the power supply to
see the location of each of these components or modules.
CAUTION
The 2000Xc Power Supply contains components that can be degraded
or damaged by electrostatic discharge. Always use a Grounded
Wriststrap and use a grounded work area when handling or servicing
the 2000Xc Power Supply.
In the following paragraphs, you are provided instructions on
removing and replacing components. Before you begin to
disassemble any parts of the power supply, ensure that the power
supply is turned off, and the main power is disconnected. After the
power supply cover is removed, wait at least two minutes to allow
capacitors to discharge. When necessary, refer to Figure 8.3 and
Figure 8.4 to help you with these procedures.