6.9.38 Timeout
You select the duration (in seconds) of the maximum allowable time for the primary
parameter to be reached during the weld in modes other than time. If the primary
parameter has not been reached, the ultrasonic energy will be turned off and the Hold
Time will start at the set timeout value. This feature is not available in Time mode.
Touching the Timeout navigation button will access the keypad to set and enter the
desired value.
6.9.39 Downspeed Tuning
Downspeed tuning enables the downspeed setup menu to be shown every time the
downspeed value is changed.
The downspeed tuning is a mechanism to hone in on a particular downspeed value by
small increments.
6.9.40 Setup Limits
Setup Limits set the minimum and maximum parameter changes allowed to be made for a
validated weld preset. When Setup Limits are enabled, a technician can change a
validated and locked weld preset’s setup parameters within the minimum and maximum
range set.
Figure 6.24 Setup Limits
NOTICE