152 100-412-234 REV. 06
6.10.36 Pressure Step Down
If the Pressure Step Down function is set to On, the system will allow Step Pressure and
Hold Pressure settings to be lower than the Weld pressure setting. See 6.9.15 Step
Pressure and 6.9.19 Hold Pressure for more information.
6.10.37 WebSrv Automation
Set to ON when Web Services are used in automation and an operator log in is not
required.
6.10.38 WebSrv AuthCheck
Authority check ensures that users logging into the power supply only have access to
features dependent on their authority level. Set to Yes to enable authority level functions
when using Web Services. See 6.10.22 Authority Check for more information.
NOTICE
Weld alarms may occur when setting Pressure Step Down to On. If
Trigger Lost or other nuisance alarms happen after a step-down
pressure, they will be ignored and not reported