234 100-412-234 REV. 06
62F
Recalibrate
Actuator
Error Code = 400
Carriage travel greater
than -0.25 after
trigger.
Run an Actuator Calibration
procedure from the Alarm
Information screen or from
Calibrate in the Main Menu.
62F
Recalibrate
Actuator
Error Code = 600
Actuator type has
changed.
Run an Actuator Calibration
procedure from the Alarm
Information screen or from
Calibrate in the Main Menu.
62F
Recalibrate
Actuator
Error Code = 700
In Horn Down, a bad
Trigger has occurred.
Run an Actuator Calibration
procedure from the Alarm
Information screen or from
Calibrate in the Main Menu.
62F
Recalibrate
Actuator
Error Code = 800
Part contact flag has
been lost.
Run an Actuator Calibration
procedure from the Alarm
Information screen or from
Calibrate in the Main Menu.
62F
Recalibrate
Actuator
Error Code = 900
Carriage travels
greater than 0.250
and less than 35 lbs.
force was developed
after part contact and
before trigger.
Run an Actuator Calibration
procedure from the Alarm
Information screen or from
Calibrate in the Main Menu.
Table B.2 Failure of Alarms and Messages, with Probable Cause and Corrective Action