258 100-412-234 REV. 06
B23
Pretrigger
Overload
The @Time is from start of
pretrigger, the frequency and
peak power is at the time of the
overload.
Check the stack.
Repair/replace the
power supply module.
B25
Post Weld Seek
O/L
An overload occurred during
post weld seek. The @ Time
and frequency change (Freq
chg) are from the start of seek.
The peak power is at the time
of the overload.
Check the stack.
Repair/replace the
power supply module.
B26
Afterburst
Overload
An overload occurred during
afterburst.
An overload occurred during
afterburst. The @ Time and
frequency (Freq Chg) is from
the start of afterburst. Peak
power is at the time of the
overload.
Check the stack.
Repair/replace the
power supply module.
Table B.6 Overload Alarms and Messages, with Probable Cause and Corrective Action
Alarm
ID
Display
Message
Alarm Condition/Cause Corrective Action

Table of Contents