260 100-412-234 REV. 06
41E
Act Recal
Suggested
A preset has been loaded
and calibration should be
run.
Additional information will
not be available if the
carriage is not at upper
limit, the actuator Novram
has failed or the palm
buttons are still pressed.
This note will be disabled
when the preset has been
recalled via external
preset selection, through
the host or sequencing.
41F Collapse Cutoff
The collapse cutoff
distance you requested
has been reached.
Manually inspect the part.
If you repeatedly get this
alarm with acceptable
parts, reset your collapse
cutoff.
Table B.7 Note Alarms and Messages, with Probable Cause and Corrective Action (Continued)
Alarm
ID
Display Message Alarm Condition/Cause Corrective Action