268 100-412-234 REV. 06
D.2.2 Logout
The logout service is only necessary when Authority Check is enabled and another user
wishes to login either from the front panel or through the web services again.
The act of logging out of the system creates an event that is stored in the Event History.
URL
http://<2000Xc IP Address>/Services/SystemLogout
POST Data
{"Sid":12345}
Successful Response
{ “ErrorCode”:0,”UserId”:”ADMIN”}
D.2.3 Get Software Version
This service is specifically used to get the 3 main versions of software running inside the
2000Xc: SBC software, Controller Board software, and Power Supply software.
URL
http://<2000Xc IP Address>/Services/GetPSVersionNum
POST Data
{"Sid":12345}
Successful Response
{"ErrorCode":0,"S/WVersion","12.0","SBCVersion","12.0","P/SVersionNum","191"}
D.2.4 Get Last Weld Result
This service request satisfies the need to get weld results on a regular basis at the end of
every weld. Typically, monitoring the 2000Xc Ready signal should trigger a request to get
the most recent weld result using this service.
URL
http://<2000Xc IP Address>/Services/GetWeldResult
POST Data
{"Sid":12345}
Successful Response
{ “ErrorCode”:0,
”1”:Value*,
”2”:Value*,
…
…
”37”:Value*}
*Some values are strings, others are numeric. Regardless of the data type, the response follows proper JSON
formatting.
See Weld History IDs for the lookup table of IDs in Table D.3.