100-412-234 REV. 06 23
Setup Checking: If you create a setup with conflicts the power supply notifies you of the specific
conflict.
System Information Screen: This is a screen that will give you information about your welding
system (e.g., cylinder size, stroke length, number of cycles). Refer to this screen when
contacting Branson for service and support.
Test Diagnostics: In Test mode you can view the ultrasonic system results using digital
readouts and bar graphs.
Timed Seek: When turned ON, will do a Seek once every minute to update horn resonant
frequency to memory. This is especially useful when the welding process affects the actual
temperature of the horn, causing a resonant frequency shift.
True Wattmeter: The controls on the power supply include a true wattmeter for accurate
measurement of power and energy.
User-Nameable Presets: You can refer to each preset by name or part number making
identification of your presets simple.
View Weld Results: From the Run Screen you can view any of the information available from
the last completed cycle.
Weld Modes: Time, Energy, Peak Power, Absolute, Collapse, and Ground Detect. The 2000Xc
Power Supply offers multiple weld modes so that you can choose the mode of control that best
meets your specific application need.
Weld Parameter Entry through Digital Keypad: User Setup is direct and easy, by selecting
the menu parameter by name and using the keypad to enter the precise value. The controls also
support entry by incrementing existing values.