Spectrophotometer Unit Specifications
Spectrophotometer Unit Specifications
Specifications
Specifications
Important
The following values may vary depending on the operating environment.
Spectrophotometer Sensor
Model name X-Rite ILS25
Measurement geometry conditions 0°/45° ANSI/ISO 5-4
Illumination Tungsten lamp with UV cut filter + UV-LED
Measurement aperture Diameter 3.55 mm
Spectral Output 31 points (400nm to 700nm 10nm gap)
Observer Angle 2°/10°
Illumination Type A, C, D50, D55, D65, D75, F2, F7, F8, F10, F11, F12
Measurement Range 0 to 150% reflection
Repetition Accuracy Maximum dEcmc0.2 (White tile)
Maximum dEcmc0.6 (Black tile)
Instrument Error Average dEcmc0.5 (BCRA tile 12 color)
Max dEcmc ≤ 1.0 (12-color BCRA tiles)
Recommended calibration frequency Once per year