11. Tech. Rep. Mode Field Service Ver. 1.0 Aug. 2005
170
bizhub 200/250/350
Adjustment / Setting
PC112-PF
Tray 3
Tray Set Tray3 Set Sensor Set
Out of
position
PC113-PF
Paper Near
Empty
Tray3 Paper Near-Empty Sensor Unblocked Blocked
PC115-PF Paper Empty Tray3 Paper Empty Sensor
Paper not
present
Paper
present
PC114-PF
Upper Side
Detect
Tray3 Lift Sensor
At upper
limit
Not at
upper limit
PC118-PF CD Size 1 Tray3 CD Paper Size Sensor 1
Maximum
value
Not at max-
imum value
PC119-PF CD Size 2 Tray3 CD Paper Size Sensor 2
Maximum
value
Not at max-
imum value
PWB-I3 PF
FD Size 1
Tray3 FD Paper Size Detection Board
Maximum
value
Not at max-
imum value
FD Size 2
Maximum
value
Not at max-
imum value
FD Size 3
Maximum
value
Not at max-
imum value
FD Size 4
Maximum
value
Not at max-
imum value
PC111-PF Take-up Lower Door Sensor Open Close
PC116-PF Pickup Tray3 Paper Take-Up Sensor
Paper
present
Paper not
present
PC121-PF
Tray 4
Tray Set Tray4 Set Sensor Set
Out of
position
PC122-PF
Paper Near
Empty
Tray4 Paper Near-Empty Sensor Unblocked Blocked
PC124-PF Paper Empty Tray4 Paper Empty Sensor
Paper not
present
Paper
present
PC123-PF
Upper Side
Detect
Tray4 Lift Sensor
At upper
limit
Not at
upper limit
PC127-PF CD Size 1 Tray4 CD Paper Size Sensor 1
Maximum
value
Not at max-
imum value
PC128-PF CD Size 2 Tray4 CD Paper Size Sensor 2
Maximum
value
Not at max-
imum value
PWB-I4 PF
FD Size 1
Tray4 FD Paper Size Detection Board
Maximum
value
Not at max-
imum value
FD Size 2
Maximum
value
Not at max-
imum value
FD Size 3
Maximum
value
Not at max-
imum value
FD Size 4
Maximum
value
Not at max-
imum value
PC125-PF Pickup Tray4 Paper Take-Up Sensor
Maximum
value
Not at max-
imum value
Symbol Panel Display Part/Signal Name
Operation Characteris-
tics/ Panel Display
10