11. Tech. Rep. Mode Field Service Ver. 1.0 Aug. 2005
178
bizhub 200/250/350
Adjustment / Setting
6
Setting the Center ID and telephone number of
the Center
1. Select [Tech. Rep. Mode] [CS Remote
Care], and touch [Detail Setting].
2. Touch [Basic] [Center ID], and input the
Center ID (five digits).
186
3. Touch [Center Phone No].
4. Input the telephone number of the Center
using the 10-Keys Pad and [P], [T], [W], [-]
keys.
186
Setting the Center ID
1. Select [Tech. Rep. Mode] [CS Remote
Care], and touch [Detail Setting].
2. Touch [Basic] [Center ID], and input the
Center ID (five digits).
186
7
Setting the Device ID
3. Touch [[Fwd] [Device ID], and input
Device ID (nine digits).
186
Setting the Device ID
4. Touch [Device ID], and input Device ID (nine
digits).
186
8
Inputting the Device telephone number
5. Touch [Device Phone No].
6. Input the Device telephone number using the
10-Key Pad and [P], [T], [W], [-] keys.
186
Setting the Respond Timeout
1. Select [Tech. Rep. Mode] [CS Remote
Care], and touch [Detail Setting].
2. Touch [Respond Timeout] and enter the
response timeout using the 10-Key Pad.
NOTE
Under normal conditions, there is no
need to change the default setting.
187
9
Inputting the AT command for initializing the
modem
1. Select [Tech. Rep. Mode] [CS Remote
Care] and touch [Detail Setting].
2. Touch [AT Command].
3. Input AT Command.
NOTE
Change this Command only when it is
necessary. (They do not need to be
changed in normal condition.)
For details on AT Command, see the man-
ual for the modem.
188
Setting the E-mail address
1. Select [Tech. Rep. Mode] [CS Remote
Care] and touch [Server Setting].
2. Touch [Initial data].
3. Select [Yes] and touch [Enter] to perform ini-
tialization.
4. Touch [Server for RX] and set POP3 Server
Address, POP3 User Name, POP3 Pass-
word, and POP3 Port Number.
188
5. Touch [RX Settings] and set E-Mail Address,
Auto-RX Check, Connection Timeout, and
APOP Authentication.
188
6. Touch [TX Settings] and set SMTP Server
Address, SMTP Port Number, Connection
Timeout, and Authentication Setting.
189
7. Touch [TX/RX Test] and press the Start key
to carry out the transmission/reception test.
Make sure that data is correctly transmitted
and received and then proceed to the next
step. If the test fails, make checks again by
following the instructions given as the error
message; then, carry out the transmission/
reception test once again.
190
Step
Procedure
Using the telephone line modem Using E-mail