11. Tech. Rep. Mode Field Service Ver. 1.0 Aug. 2005
180
bizhub 200/250/350
Adjustment / Setting
11.11.3 Software SW setting for CS Remote Care
NOTE
In case you changed bit data by accident, be sure to restore the previous state.
A. Input procedure
1. Select [
Tech. Rep. Mode] [CS Remote Care] [Detail Setting], and touch [Software
Switch Setting].
2. Touch [Mode Selection], and input the SW number (two digits) using the 10-Key Pad.
3. Touch [Bit Selection], and select SW bit number using the arrow keys, and input 0 or 1
using the 10-Key Pad.
(For setting by hexadecimal numbers, touch [HEX Selection], and input using the 10-
Key Pad or A to F keys.)
4. Touch [Enter].
NOTE
About functions of each switch, see to “B. List of software SW for CS Remote
Care.
B. List of software SW for CS Remote Care
NOTE
Do not change any bit not described on this table.
SW No. Bit Functions 0 1 Default
SW 01 0 Dial Mode Pulse Tone 1
1 Reservation 0
2 Reservation 0
3 Reservation 0
4 Baud rate *1 *1 0
5*1*10
6*1*10
7*1*11
SW 02 0 Emergency transmission Do not call Call 1
1 Date specified transmission Do not call Call 1
2 Reservation 0
3 Reservation 0
4 Reservation 0
5 Auto call on the IC Life Do not call Call 1
6 Reservation Do not call Call 1
7 Reservation 0
SW 03 0 Reservation 0
1 Auto call on the toner empty Do not call Call 1
2 Reservation 0
3 Reservation Do not call Call 1
4 to 7 Reservation 0
SW 04 0 to 7 Reservation 0

Table of Contents