11. Tech. Rep. Mode Field Service Ver. 1.0 Aug. 2005
186
bizhub 200/250/350
Adjustment / Setting
11.11.8 Detail on settings
A. System Input
B. ID Code
C. Detail Setting
(1) Basic
Functions To select the system type for remote diagnosis.
Use Use to newly build or change the system.
Setting/
Procedure
Select E-Mail or Modem.
The default setting is “E-Mail”.
“E-Mail” Modem
Functions To register the Service ID.
Use Use when registering and changing Service ID.
Setting/
Procedure
Enter a 7-digit code from the 10-Key Pad. (0000001 to 9999999)
Registration
Touch [ID Code] and enter the Service ID.
Touch [ID code] to register the ID.
The [Detail Setting] will appear when the ID has been registered.
Functions Execute the primary setting.
Use
Use to change the set contents.
Use to register the machine to the CS Remote Care Center.
Setting/
Procedure
1. Call the Tech. Rep. Mode to the screen.
2. Touch [CS Remote Care].
3. Touching the [Detail Setting] will display the primary setting.
Primary Setting
Set the Center ID, Device ID, and the phone No.
When e-mail is selected for system and all setup procedures are completed, E-mail
address of the Center is displayed.
* When entering the phone No, 10-Keys and keys on the screen have following meanings.
[-] Pose : Waits to start transmitting after dialing
[W] Wait : Detects the dial tone of the other end
[T] Tone dial : Carry out tone dialing
[P] Pulse dial : Carry out pulse dialing
[*],[#] : To be used as necessary
Initial Transmission
Touching the Initial Transmission key will sent the information to the CS Remote Care
Center to register the machine.
(Only when the Modem is selected on the system Input.)