Field Service Ver. 1.0 Aug. 2005 11. Tech. Rep. Mode
187
bizhub 200/250/350Adjustment / Setting
(2) Date & Time Setting
(3) RAM Clear
(4) Communication Log Print
(5) Software Switch Setting
(6) Respond Timeout
Functions • To set the data and time-of-day
Use • Use to set or change the date and time-of-day.
Setting/
Procedure
1. Call the Tech. Rep. Mode to the screen.
2. Touch [CS Remote Care].
3. Touch [Detail Setting] to access Date & Time Setting.
4. Enter the date (month, day and year), time-of-day, and the time zone from the 10-Key
Pad.
5. Touch [Job Start] to start the clock.
Functions
• To clear the following data at the Center
ID Code, Primary Setting, Date/Time Input (Time Zone), Software SW Setting and AT
Command.
Use
• To be used for setting CS Remote Care.
• To be used for reset the every data of the Center to default.
NOTE
• If RAM Clear is selected during transmission, RAM clear processing will be
implemented at the time the transmission is completed regardless of whether it
is done properly or not.
Setting/
Procedure
• The default setting is “NO”
YES “NO”
Functions • To print out the Communication Log.
Use • Use to output and use the Communication Log.
Setting/
Procedure
1. Call the Tech. Rep. Mode to the screen.
2. Touch [CS Remote Care].
3. Touch [Detail Setting] to access Communication Log Print.
4. Load Tray 1 or Bypass Tray with A4R or 81/2 x 11 paper.
5. When the Basic screen reappears after the Tech. Rep. mode has been exited, an out-
put of the communication log is produced.
Functions • To change the CS Remote Care settings.
Use • To change the settings for CS Remote Care as necessary.
Setting/
Procedure
☞ For procedures on settings, see 180.
Functions
• To set retry intervals for an e-mail transmission error.
• This setting can be made only when [E-Mail] is selected in System Input.
Use • To change the retry intervals for an e-mail transmission error.
Setting/
Procedure
• The default setting is “30 min.”
10 to 1440 min.