Field Service Ver. 1.0 Aug. 2005 11. Tech. Rep. Mode
189
bizhub 200/250/350Adjustment / Setting
<Auto-RX Check>
<Connection Timeout>
<APOP Authentication>
(3) TX Settings
<SMTP Server Address>
<SMTP Port Number>
<Connection Timeout>
Functions
To set whether or not to use Auto-RX Check and the time interval for the POP3 server
used for CS Remote Care.
Use
To select not to use Auto-RX Check.
To change the time interval for Auto-RX Check.
Setting/
Procedure
The default setting is “OFF”
“OFF” (1 to 120)
Functions To set the timeout period for connection during reception.
Use To change the timeout period for connection during reception.
Setting/
Procedure
The default setting is “60 sec”
“60 sec” (30 to 300)
Functions To set whether or not to enable APOP authentication during reception.
Use To enable APOP authentication during reception.
Setting/
Procedure
The default setting is “OFF”
ON “OFF”
Functions To set the SMTP server address for transmission used for CS Remote Care.
Use
To set the address of the SMTP Server.
The SMTP server address can be set as an IP address or domain name.
Setting/
Procedure
<IP Address>
IP address Version 4 format
[0 to 255] . [0 to 255] . [0 to 255] . [0 to 255]
<FQDN>
Enter the domain name.
Functions To set the SMTP port number for transmission used for CS Remote Care.
Use To set the port number of the SMTP Server.
Setting/
Procedure
The default setting is “25”
“25” (1 to 65535)
Functions To set the timeout period for transmission.
Use To change the timeout period for connection during transmission.
Setting/
Procedure
The default setting is “60 sec”
“60 sec” (30 to 300)