11. Tech. Rep. Mode Field Service Ver. 1.0 Aug. 2005
192
bizhub 200/250/350
Adjustment / Setting
0010 RX FIF0 ERROR
(when Read / Write error occurs at RX FIF0)
Contact responsible person of
KONICA MINOLTA.
0011 Baud Rate ERROR
(When selected Baud Rate is out of the specifica-
tion (9600 bps to 38400 bps).)
Check the Baud rate of the
software DipSW.
0012 TX FIF0 Level Error
(When the threshold of the selected TX FIF0 is
not error value (1, 3, 9, 13).)
Contact responsible person of
KONICA MINOLTA.
0013 RX FIF0 Level Error
(When the threshold of the selected RX FIF0 is
not error value (0, 4, 8, 14).)
Contact responsible person of
KONICA MINOLTA.
0014 Receiving Data Over Error
(When the data whose size exceeds the transmit-
ting RING buffer is requested.)
Contact responsible person of
KONICA MINOLTA.
0015 Status Error
(During modem operation is being confirmed)
Contact responsible person of
KONICA MINOLTA.
0016 Status Error (During receiving) Contact responsible person of
KONICA MINOLTA.
0017 Status Error
(During line is being shut down)
Contact responsible person of
KONICA MINOLTA.
0018 Machine ID has already been registered
(Request telegram 2 (SET-UP) comes from the
main unit that has already registered Machine
ID.)
Set the initial registrations
again for all including the host
side.
0019 Center ID Error
(Center ID of the host is not identical with the one
of start request telegram.)
Check Center ID setting of the
main unit side.
Check Center ID setting of the
main unit side.
001A Device ID inconsistency
(Device ID of the host is not identical with the one
of start request telegram.)
Check Device ID setting of the
main unit side.
Check the setting of the host
side.
001B Device ID Unregistered
(Request telegram 2 (Constant data transmitting,
Emergency call) comes from the main unit that
has not registered Machine ID yet.)
Check Device ID setting of the
main unit side.
Check the setting of the host
side.
001C Grammar Error
(Received response telegram is unregulated for-
mat.)
Contact responsible person of
KONICA MINOLTA.
001D Impossible to change (Unchangeable items)
(Host requests to change the setting of items
which are not allowed to change.)
Contact responsible person of
KONICA MINOLTA.
001E Impossible to change (During printing)
(Setting cannot be changed because the setting
change is made during the machine is printing or
starts printing.)
Try again when the machine is
not printing.
001F Impossible to change (Unread items)
(The host tries to make writing on the items the
current value has not been read.)
Contact responsible person of
KONICA MINOLTA.
Error code Error Solution