EasyManua.ls Logo

Develop ineo 350 - Page 431

Develop ineo 350
770 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11. Soft Switch List Field Service Ver. 1.0 Aug. 2005
62
FK-503
Adjustment / Setting
NOTE
The features with (*) are settable by users. <*>: Soft switch setting
NOTE
The features with (*) are settable by users. <*>: Soft switch setting
MODE Factory setting bit
014
Bit: 7654 3210
0000 0001
HEX:01
Bit Feature
Logic
Description
01
7 Select redialing interval
for resending document.
Bit 7-5:
000 10ïb
6 001 30 sec
5 010 60 sec
011 120 sec
100 180 sec
Others Not available
1 Broadcast transmission
setting confirmation win-
dow. <*>
Bit 1-0: 00 Not display
0
01 Confirms settings at broadcast trans-
mission
10 Confirms settings (single destination/all
destinations)
11 Not available
MODE Factory setting bit
016
Bit: 7654 3210
0100 0000
HEX:40
Bit Feature
Logic
Description
01
6 Use of extra telephone.
<*>
No
Yes
5 Mail mode: Print date &
time received <*>
No Ye s
4 Mail mode: Position of
print date & time received
<*>
Inside
doc.
Outside
doc.
This is valid only when “(MODE 016
Bit5)” sets Yes.
1 RX Time Stamp: Print
date & time received <*>
No Ye s
0 RX Time Stamp: Position
of print date & time
received <*>
Inside
doc.
Outside
doc.
This is valid only when “(MODE 016
Bit1)” sets Yes.

Table of Contents

Related product manuals