Field Service Ver. 1.0 Aug. 2005 11. Soft Switch List
97
FK-503Adjustment / Setting
NOTE
MODE Factory setting bit
192
Bit: 7654 3210
0000 0000
HEX:C0
Bit Feature
Logic
Description
01
7 Select order of displaying
year to date.
(Corresponding to each
region)
Bit 7-6: 00 Year-Month-Date Order of displaying
date in OPE display
6 01 Not available
10 Date-month-year
11 Month-date-year
MODE Factory setting bit
197
Bit: 7654 3210
0000 0000
HEX:C0 (For U.S.)
HEX:C1 (For Europe)
Bit Feature
Logic
Description
01
7 Daylight saving function Not
available
Available
6 Display ON/OFF switch of
Daylight saving
OFF
ON
3 Daylight saving pattern Bit 3-0:
0000 Pattern 1 For the details of
patterns 1 to 6, see
NOTE below.
2
0001 Pattern 2
1 0010 Pattern 3
0 0011 Pattern 4
0100 Pattern 5
0101 Pattern 6
Others Not available
Start Time End Time
Pattern 1 2:00 am on 1st Sunday, April 2:00 am on last Sunday, October
Pattern 2 2:00 am on last Sunday, March 2:00 am on last Sunday, October
Pattern 3 2:00 am on last Friday, April 2:00 am on last Thursday, September
Pattern 4 2:00 am on last Sunday, March 2:00 am on last Sunday, September
Pattern 5 2:00 am on 1st Sunday, September 2:00 am on last Sunday, April
Pattern 6 2:00 am on last Sunday, October 2:00 am on last Sunday, March