11. Soft Switch List Field Service Ver. 1.0 Aug. 2005
98
FK-503
Adjustment / Setting
NOTE
• The features with (*) are settable by users. <*>: Soft switch setting
• Some machines cannot receive calls.
Care must be taken when you set the ringing count to 10 or more.
• For PSTN1, refer to MODE 019.
MODE Factory setting bit
198
Bit: 7654 3210
1101 0000
HEX:D0
Bit Feature
Logic
Description
01
7 TX forwarding to adminis-
trator <*>
No
Yes
6 TX forwarding of scanner
function to administrator
<*>
No
Yes
5 Result report TX forward-
ing to administrator
Bit 5-4: 00 Not output
4
01 Output for
incomplete TX
10 Always output
11 Not available
MODE Factory setting bit
212 (PSTN1)
232 (PSTN2)
Bit: 7654 3210
0000 0000
HEX:40 (For U.S.)
HEX:00 (For Europe)
Bit Feature
Logic
Description
01
7 Select DP make rate. Bit 7-6:
00 33 % Specify the DP signal
make ratio.
6
01 40 %
Others Not available
MODE Factory setting bit
249
Bit: 7654 3210
0000 1000
HEX:08
Bit Feature
Logic
Description
01
7 Specify the ringing count
of auto receiving call
(PSTN2) <*>
Bit 7-3: 00000 0 Specify the PSTN2 ring-
ing detection count. The
ringing count is the num-
ber of rings until the
machine automatically
starts receiving a call.
6
00001 1
5|
4 10100 20
3 Others Not available