13. Timing 259
13.4.1 Learn Timing
Learn Timing allows you to assign a cue's wait time value by manual executing the cues with
the Go key when the learn timing option is selected for the cuelist. If a timecode clock
assigned to that list is running when learn timing is enabled then the wait value recorded into
the wait cell will be a timecode value.
To use Learn Timing with timecode:
1. Open , Choose : open the Cuelist window of the required cuelist.
2. Option s → Cuelist Optio ns : open the Cuelist pane of the Cuelist Options window.
3. Select En able Timeco de , and choose a timecode source. Close the Options window.
4. In the Cuelist window, click View Timecod e. The Timecode Toolbar will open.
5. If your timecode source is not currently running, click Simulate on the Timecode
Toolbar to have the console create a timecode source. Controls for the timecode will
appear.
6. In the Cuelist window, select Le arn Timing.
7. Start the timecode, and press the Go key when the timecode reaches the time that you
want each cue to go. A timecode frame value will appear in the Wait cell for each cue.
8. When you have finished, deselect L ear n Timing.
Now when you run the timecode, the cues will be triggered when the timecode reaches each
cue's assigned frame. For more information on timecode, see MIDI Timecode.
To use Learn Timing without timecode:
1. Open , Choose : open the Cuelist window of the required cuelist.
2. Ensure that Enab le Timeco de is not selected.
3. Select L ea rn Timin g.
4. Press the Go key to run the first cue, and again to run subsequent cues after the
required time interval. A time value equivalent to the duration between Go presses will
appear in the Wait cell for each cue.
5. When you have finished, deselect L ear n Timing.
Now when you run the first cue, the subsequent cues will be triggered at the same intervals
as when you ran them manually.
Tip: Learn Timing will only set a trigger on a cue that is currently set to Halt - that is, it has
an empty Wait cell. To remove existing wait times from cues, select the wait cell(s) and