28. Visualizer Connectivity 465
28.5 Configuing the Console
28.5.1 Enabling the Visualizer Stream on the Console
Navigate to the start screen of Hog 4 OS and click on the Control Pan el button.
Select the Startup tab.
Enable the "Run Visualizer Stream" button and click OK.
28.5.2 Configuring a Show for Visualizer Connectivity
1. Load a new or existing show file on your console.
2. Open the network window (Setup Netwo rk).
3. Click on the visualizer node listed in the network window.
4. Click on the Settings button located at the top of the network window. This will open
the visualizer settings window.
5. Enter the IP address of the visualizer PC into the IP address field.
If a visualizer is already running on the network you can use the "detected
visualizers" drop down menu to auto-populate the IP address and visualizer
protocol and manufacturer fields.
In you are using WYSIWYG, all steps listed in WYSIWYG Configuration
must be completed in order for WYSIWYG to be listed as detected visualizer.
6. Select the appropriate visualizer protocol and manufacturer using the drop down
menus. Use of the CITP protocol for visualizer streaming to Capture requires Capture
Version 2019.0.13 or greater.
7. Click OK to apply the changes. The Hog 4 console will now stream all of the universes
directly to visualizer using the FixtureNet port on the back of the console.
28.6 Autofocus
Visualizers can send information back to your Hog console to allow lights to be automatically
positioned to a particular location on stage, rather than individually positioning the fixtures
using the console’s controls. This feature is called Autofocus and works when using the Hog
Connectivity protocol for visualizer streaming.
When Autofocus is properly enabled and configured, selecting and deselecting fixtures as
well as assigning intensity, iris, pan, tilt, and CMY colour mixing values to fixtures in the
visualizer application results in those same selections and values appearing in the active
editor or programmer on the Hog console.
Please refer to the users manual for each respective visualizer application for further details