CHAPTER 4 PARAMETER
Automatic Operation Setting Parameter 4-55
4
(3) At-start reverse rotation homing profile1 (equivalent to homing profile 3 of FALDIC-α Series)
After homing is started, a travel occurs in the direction opposite to the starting direction for homing
by the specified reverse traveling unit amount for homing while the reference signal for homing
(deceleration starting signal) is searched for.
This profiles used if the machine stopping position is larger than the reference signal for homing
(deceleration starting signal) or reference signal for shift operation.
[Parameter setting example]
PA1_
No. Name Setting
Default
value
Change
01 Control mode selection 6: Extension mode 0 Power
PA2_
No. Name Setting
Default
value
Change
06 Homing speed 500.00 [r/min] 500.00 Always
07 Creep speed for homing 50.00 [r/min] 50.00 Always
08 Starting direction for homing 0: Forward rotation 0 Power
09
Reverse traveling unit amount for
homing
20000 [units] 0 Always
10
Homing direction after reference
signal detection
0: Forward rotation 0 Power
11
Reference signal for shift
operation
1: Encoder Z-phase 1 Power
12
Reference signal for homing
(Deceleration starting signal)
0: Home position LS 0 Power
13
Home position LS signal edge
selection
0: Rising edge 0 Power
14 Home position shift unit amount 1000 [units] 1000 Always
15
Deceleration operation for creep
speed
0: Reverse rotation is disabled 0 Power
16
Home position after homing
completion
0 [units] 0 Always
17 Home position detection range
0: Always ON after homing
completion
0 Always
18
Deceleration time at OT during
homing
100.0 [ms] 100.0 Always
24
Selection of operation at OT
during homing
0: Reverse rotation
0 Power
Because rotation reverses in the direction opposite to the OT direction upon OT detection to
detect the reference signal for homing (deceleration starting signal) and reference signal for shift
operation, secure homing is realized. The reverse rotation after OT detection follows (2) OT
reference homing profile.