CHAPTER 6 KEYPAD
6-24
Monitor Mode
6
(21) OL thermal value (displayed digits: unsigned three digits)
The load ratio to the load alarm level is displayed in
percent. An overload alarm is caused if this value reaches
100. The minimum increment is 1. The displaying range is
from 0 to 100%.
(22) Regenerative resistor thermal value (displayed digits: unsigned three digits)
The regeneration load ratio to the regenerative resistor
overheat alarm level is displayed in percent. A regenerative
resistor overheat alarm is caused if this value is 100. The
regeneration load ratio is calculated for amplifier frame
no.2 or above if PA2_65 (regenerative resistor selection) is
set at 1 (internal resistor).
The minimum increment is 1. The displaying range is from
0 to 100%.
(23) Power (w) (displayed digits: signed three digits)
The servomotor power (w) is displayed in percent to the
rating.
The data is displayed in the range from 0 to 900% in
increments of 1.
(24) Motor temperature (displayed digits: unsigned three digits)
The servomotor temperature is displayed. The range from
0 to 120°C is displayed in increments of 1°C.