CHAPTER 14 PC LOADER
14-22
Detail Description of Function
14
Tracing procedure
[1] Select the desired waveform.
[2] Enter trigger conditions.
[3] Select the sampling time.
[4] Enter the trace number starting at the trigger position.
[5] Press the "START/STOP" button to start to trace.
If trigger conditions are satisfied, the waveform is acquired and the procedure is automatically
stopped.
Waveform that can be acquired
Same as that of real time trace
Trigger setting
Both analog and digital waveforms can be used for the trigger setting*.
* The trigger setting is only for the single channel.
Analog trigger setting
Digital trigger setting