CHAPTER 14 PC LOADER
14-46
Parameter Conversion Tool
14
Contents of the conversion result screen
The following contents are displayed on the conversion result screen.
(1)
No. FALDIC-W parameter nos. Parameter
before
conversion
(2)
Setting value Setting values of parameter file for FALDIC-W
before conversion
(3)
PA ALPHA5 Smart parameter nos.
(4)
Setting item ALPHA5 Smart parameter names
(5)
Setting value ALPHA5 Smart setting values (result from
conversion)
(6)
Setting range ALPHA5 Smart parameter setting range
Parameter after
conversion
(7)
Initial value ALPHA5 Smart parameter initial values
The conversion results of the parameter are color coded in (3)(4)(5) on the conversion result screen.
Display colors in
(3)(4)(5)
Conversion results
Characters in
black
Parameters not included in conversion work (default)
Characters in
blue
Converted parameters
Characters in red Parameters not included in the range as the result of conversion
(default)
(Yellow) Parameters that need to be set again or adjusted as appropriate.
(Green) Parameters that cannot be converted due to lack of required
functions
[8] Saving the conversion result
■ ALPHA5 Smart parameter file - Save
Save the conversion result into the ALPHA5
Smart parameter file.
Click the “Save” with ALPHA5 Smart
parameter to display the window on the right.
Input the file name and click “Save”.
・Make sure to check all the conversion results in the ALPHA5 Smart parameter file of
conversion result and adjust accordingly before writing the data into the amplifier.
・To adjust the conversion result, use “parameter edit” in “ALPHA5 Smart LOADER”.
・After the conversion result have been checked and adjusted appropriately with