EasyManua.ls Logo

GRASS VALLEY KAYENNE - Router Indexing; Add Router Indexing to Shows Created with Earlier Versions; Router Control of Aux Buses

GRASS VALLEY KAYENNE
415 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Device Control
About R-MEM (Router Memory Registers)
256
to send commands to the external router to protect or un-protect the router destination
associated with the selected switcher source. The button for the current setting of the
selected switcher source will be highlighted. The following protections are available:
Protection OffSource can be changed at any time by any control panel,
Protection Off All DestinationsSame as Protection Off but for all destinations.
Protection OnSource cannot be changed by another Control Panel, but may be
changed from the GV Switcher system,
Protection On All DestinationsSame as Protection On but for all destinations.
On Air ProtectionThe source cannot be changed by another control panel when it is
on-air, but may be changed manually from the GV Switcher system. The source will also
not be changed by an R-MEM recall, and
On Air Protection All DestinationsSame as On Air Protection but for all destinations.
External router system panels can place protections on router destinations. The first panel
placing a protection controls that destination. The GV Switcher system will not be able to
change router sources feeding router destinations protected from another panel, and vice
versa.
Router Indexing
The GV Switcher system uses indexing to manage router connections (instead of router
names), therefore you can change router source and destination names without affecting
router source control.
Add Router Indexing to Shows Created with Earlier Versions
To add indexing to shows created on switcher systems with software earlier than 9.0, you
will need to load the show then create a new show with router indexing enabled.
1 In the File Ops, Show Files menu, load a show file created using an earlier version of
software.
a Navigate to and select the show using the System Storage or Remote Storage tabs
and navigation buttons in the Directory Search pane (left).
b Select
Load Show in the Show Create & Load menu pane.
2 In the Eng Setup, Router menu, select Index in the Type menu pane.
3 In the File Ops, Show Files menu, select Create Show in the Show Create & Load menu
pane.
4 Name your show by selecting the Show Name data pad, entering the name in the pop-
up keyboard, and selecting
Enter.
5 Select your preferences in the Create Show pane (right), and select
Create.
Router Control of Aux Buses
The GV Switcher can be configured to allow Encore and Prelude control systems, including
standalone Prelude Control Panels, to control Aux bus source selections.
All switcher Aux buses can be configured to appear on the Router Control System. Aux
buses that are not enabled for router control are seen as being ‘protected’ by the switcher
to the Router Control System. In other words, an Aux bus’ current status (source selection) is
displayed but it cannot be controlled by the Router Control System.
If an Aux bus is enabled for router control, then the source can be changed by a configured

Table of Contents