Chapter 6 Error List6.1 Error Level Control
204
Chapter 6 Error List
6.1 Error Level Control
Program run (Application only)
Error level
System error
assignment source
Error No.
(HEX)
Display
(7-segment
display, etc.)
Error list
(Application
only)
Error LED
output
(MAIN only)
Other parameter No. 4 = 0 Other parameter No. 4 = 1
Error reset
(Application
only)
Remarks
Main application 800 to 88F
Main core 890 to 8AF
PC 8B0 to 8DF
Secret level
TP 8E0 to 8FF
Special error level
provided for
maintenance
purposes
Main application
Main core -
PC
PC (Update tool)
TP
Main application 200 to 24F
Main core -
PC 250 to 29F
PC (Update tool) 2A0 to 2CF
TP 2D0 to 2FF
Main application 900 to 93F
Main core 940 to 97F
PC 980 to 9AF
PC (Update tool) 9B0 to 9BF
TP 9C0 to 9FF
Main application A00 toA6F
Main core A70 to A9F
PC AA0 to ACF
Message
level
TP AD0 to AFF
(Battery and
fieldbus
errors will
be
registered in
an error
list.)
Enabled
Status display, input
error, etc.
Main application
Main core -
PC
PC (Update tool)
TP
Main application 400 to 4CF
Main core -
PC 4D0 to 4DF
PC (Update tool) 4E0 to 4EF
Operation-
cancellation
level
TP 4F0 to 4FF
The program in which the error
generated will be cancelled.
(Except for axis errors, a
cancellation factor is present only
for the moment the error occurs.)
* However, in the case of an error
requiring servo OFF or all-axis
servo OFF, all programs other
than the “I/O processing program
at operation/program abort” will
be cancelled. (X-SEL J/K Main
application version 0.17 or later)
All programs other than the
“I/O processing program at
operation/program abort”
will be cancelled. (Except
for axis errors, a
cancellation factor is
present only for the
moment the error occurs.)
Enabled
Errors affecting
operation. The
system will attempt
to reset minor errors
below this level
using an auto-reset
function via external
active command
(SIO/PIO)
(application only).