13-86 INSTRUMENTS (AND AVIONICS) / PITOT-STATIC-ANGLE OF ATTACK (AOA) SYSTEM
ICON A5 / MAINTENANCE MANUAL CHANGE C2
4. Reconnect the tubes in their original order.
5. Perform a Pitot-Static-AOA System Leak Check to confirm no leaks at the MSC connections
before proceeding. (See “Pitot-Static-AOA Leak Test Procedures” on page 13-70.)
VERIFICATION METHOD:
If no leaks are found proceed to Check Wing Connections. (See “Check Wing Connections” on page
13-86.)
13.8.2.2.2 Check Wing Connections
Use the following procedure to check the wing connections for leaks.
TASK INFORMATION:
Type of Maintenance
Line
Level of Certification
LSA-RM
Task Specific Training Required
No
Special Tools Required
Preston PS-525 Pitot-Static Test Set (or equivalent)
Parts Required
None
Aircraft System and Number
10—Instruments (and Avionics)
Consumables
None
1. Locate the left wing hinge. (See “Remove Left Wing” on page 17-9. Steps one to three.)