11.6.14.2Error13-2(emergencycodeFF00h)
Cause: Sercos option: Illegal communication phase
Suggested steps:
Error during phase switching or invalid phase switching. Please check the settings in
the master!
Thedevicewasprobably
disconnectedfromthe
mastercontroller,orthe
masterisoverloaded.
l Pleasecheckthebussystemconnection.Try
toreplacethecables.
l Pleasetrytoreducecomputationalloadonthe
master.
l Trytoincreasethemastercycletime.
11.6.14.3Error13-3(emergencycodeFF00h)
Cause: Sercos option: Optical fiber break
Suggested steps:
Please check the function of the optical fibres and the correct wiring.
11.6.14.4Error13-4(emergencycodeFF00h)
Cause: Sercos option: Receive data disturbed
Suggested steps:
Disturbed receive data due to distortion. Lightwave power does not match to the
cable length. Please check the cable length!
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
362
11 Alarms & warnings
11.6.14.5Error13-5(emergencycodeFF00h)
Cause: Sercos option: MST failure
Suggested steps:
Missing master sync telegram. Please check the wiring!
ThisispossiblyanEMC
issue.Thisisverylikelyifthe
problemoccurswhen
switchingonmotorcontrol
and/orwhenconnectingDC
linkpowersupply.
l Pleasecheckthedevicecablingforproper
connection.
l Pleasecheckdevicegrounding,i.e.the
connectiontoametalbackplaneandcabinet
connectiontoearth.
l Checkmotorgroundingandmotorcable
length.
Thedevicewasprobably
disconnectedfromthe
mastercontroller,orthe
masterisoverloaded.
l Pleasecheckthebussystemconnection.Try
toreplacethecables.
l Pleasetrytoreducecomputationalloadonthe
master.
l Trytoincreasethemastercycletime.