11.6.14.6Error13-6(emergencycodeFF00h)
Cause: Sercos option: MDT failure
Suggested steps:
Missing master data telegram. Please check the wiring!
Thedevicewasprobably
disconnectedfromthe
mastercontroller,orthe
masterisoverloaded.
l Pleasecheckthebussystemconnection.Try
toreplacethecables.
l Pleasetrytoreducecomputationalloadonthe
master.
l Trytoincreasethemastercycletime.
11.6.14.7Error13-7(emergencycodeFF00h)
Cause: Sercos option: 2 drives with same address in the ring
Suggested steps:
Please check the configured SERCOS address (parameter 3000 for SERCOS II /
parameter 11040 for SERCOS III)
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
363
11 Alarms & warnings
11.6.14.8Error13-8(emergencycodeFF00h)
Cause: Sercos option: Phase upshift failure
Suggested steps:
Error during phase switching (up-shift) by master. Please check the settings in the
master!
Thedevicewasprobably
disconnectedfromthe
mastercontroller,orthe
masterisoverloaded.
l Pleasecheckthebussystemconnection.Try
toreplacethecables.
l Pleasetrytoreducecomputationalloadonthe
master.
l Trytoincreasethemastercycletime.
11.6.14.9Error13-9(emergencycodeFF00h)
Cause: Sercos option: Phase downshift failure
Suggested steps:
Error during phase switching (down-shift) by master. Please check the settings in the
master!
Thedevicewasprobably
disconnectedfromthe
mastercontroller,orthe
masterisoverloaded.
l Pleasecheckthebussystemconnection.Try
toreplacethecables.
l Pleasetrytoreducecomputationalloadonthe
master.
l Trytoincreasethemastercycletime.