11.6.16.15Error15-16(emergencycodeFF00h)
Cause: Selected switch frequency is not possible
Suggested steps:
Change switch frequency or disable PWM-frequency switching
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.
11.6.16.16Error15-17(emergencycodeFF00h)
Cause: Autotuning mode not supported (in this configuration)
Suggested steps:
Please use other autotuning mode or tune by hand
11.6.16.17Error15-18(emergencycodeFF00h)
Cause: Error in power fail initialization
Suggested steps:
Check power fail parameters or disable function
ID No.: 0842.26B.5-01Date: 09.2020
ServoOne- Device Help
374
11 Alarms & warnings
11.6.16.18Error15-19(emergencycodeFF00h)
Cause: Error in camming or electronic gearing initialization
Suggested steps:
Check parameter or IEC configuration
11.6.16.19Error15-20(emergencycodeFF00h)
Cause: Error in configuration of CAM module
Suggested steps:
Check for even number of configured cam edges. All configured cam edges have to
be in ascending order.
11.6.16.20Error15-21(emergencycodeFF00h)
Cause: Dataset to be loaded is not valid
Suggested steps:
Check Parameter PRam_PARA_DataSetLdVal
Thisissueisprobably
causedbyanunsuitable
parametersetting.
l Saveyourparametersetforalaterrestore.
l See'historyofparameterchanges'andundo
thelatestchanges.
l Pleasecheckyourparametersetfor
implausiblesettings.
l Pleasesetdevicetofactorysetting,restart,and
seeiftheerroroccursagain.
l Whenreportingthiserrortoyourservice
partner,pleaseincludeyourdevice's
parametersetting.