2WA/2NJ/2RK-2
9-3
Form feed time-out value H9 Value in units of 5 seconds (0 to 99). 6
1 (100V)
Reduction (100V model only) J0 0: 100%
5: 70 %
6: 81 %
7: 86 %
8: 94 %
9: 98 %
0
Auto linefeed mode (100V model
only)
(Japanese emulation only)
J7 0: Auto linefeed
1: No auto linefeed
0
Horizontal offset (100V model
only)
K0 -7 to +7 (Integer), unit: cm 0
K1 -99 to +99 (Decimal), unit: 1/100 cm 0
Vertical offset (100V model only)* K2 -7 to +7 (Integer), unit: cm 0
K3 -99 to +99 (Decimal), unit: 1/100 cm 0
Kanji font number setting
(100V model only)
K4 0: Same as V7
1: Mincho 40 dots
2: Gothic 40 dots
5: Mincho 48 dots
6: Gothic 48 dots
0
New/old JIS code switching
(100V model only)
K6 0: JIS X 0208: 1990
1: JIS X 0208: 1978
8: JIS X 0213: 2004
0
KIR mode N0 0: OFF
2: ON
2
Duplex printing mode selection N4 0: OFF
1: Long-edge mode (long-edge bind)
2: Short-edge mode (Short-edge bind)
0
Sleep timer time-out time N5 1 to 240 minutes 60
Eco Print mode N6 0: OFF
2: ON
0
Resolution N8 0: 300dpi
1: 600dpi
3: 1200dpi
1
Default emulation mode P1 6: PCL6 (except PCL XL)
9: KPDL
6
9 (120V)
Carriage-return action P2 0: Ignores 0x0d
1: CR
2: CR+LF
1
Linefeed action P3 0: Ignores 0x0d
1: LF
2: CR+LF
1
Items FRPO Setting value Factory set-