EasyManua.ls Logo

Kyocera TASKalfa 8002i

Kyocera TASKalfa 8002i
1627 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2WA/2NJ/2RK
6-46
Contents
Correct the input of the sensor data which is described in the bundled sheet at exchanging a loop
sensor and fuser motor.
Purpose
Execute to exchange the loop sensor or the conveying unit.
Execution
1.Press the [Start] key.
2.Select the item to execute.
* :The screen for executing is displayed.
Execution: Set Loop Sensor
1.Select [Scanning Board1].
2.Press [+] [-] key and then input the sensor data value of bundled
sheet DATA1.
3.Select [Scanning Board2].
4.Press [+] [-] key and then input the sensor data value of bundled
sheet DATA2.
5.Press the [Start] key and then fix the setting value.
U052 Fuser motor control setting
(Message: Set Fuser Motor Speed)
Items Contents
Set Loop Sensor Input of the loop sensor data value
Loop Sensor Control Setting of the loop sensor detection control
Set Loop Sensor Valid Set if the loop sensor is or not.
Chk Loop Sensor Displays the loop sensor value.
Items Contents Setting
range
Data
variation
Initial
setting
Scanning
Board1
Setting of Scanning Board1 150 to 250 0.01V 0
Scanning
Board2
Setting of Scanning Board2 130 to 230 0.01V 0
How to read the sensor
data value