2WA/2NJ/2RK
6-68
Contents
Set the error detection threshold for white lines correction and display the abnormal pixel count.
Purpose
Execute at replacing the CIS, DP main PWB or CIS roller.
Setting
1.Press the [Start] key.
2.Select the item to set.
3.Change the setting value by using [+] [-] key or the numeric keypad.
* :Normally do not change the threshold from the initial value of 112.
Increase the value if white lines appear while the CIS roller/glass is not dirty.
Reduce the set value if thin lines disappear depending on the original to use.
Set in the range of 50 to 200. (In the case of out of range, it may affect the image output)
4.Press the [Start] key to set the setting value.
U091 White lines correction setting
(Message: Set White Line Correction)
Items Contents Setting range Data
variation
Initial
setting
Coeffi-
cient(R)
Displays the red pixel error counts 0 to 8191 - -
Coeffi-
cient(G)
Displays the green pixel error counts 0 to 8191 - -
Coeffi-
cient(B)
Displays the Blue pixel error counts 0 to 8191 - -
Threshold(R) Sets the red error detection threshold 0 to 1023 - 112
Threshold(G) Sets the green error detection threshold 0 to 1023 - 112
Threshold(B) Sets the blue error detection threshold 0 to 1023 - 112
Threshold
(Abnormal)
Sets the abnormal pixel threshold 0 to 8191 - 75
Mode Set the white lines correction mode 0: No correc-
tion
1: Correction
2: Test mode
-0
Execute Execute retaining the white Refer ence
data
---